-- *********************************************************************
-- CISCO-ST-TC.my: Storage TC Mib
--
-- September 2002, Vinay Gaonkar
--
-- Copyright (c) 2002, 2003, 2004, 2005 and 2006 by cisco Systems, Inc.
-- All rights reserved.
--
-- *********************************************************************CISCO-ST-TC DEFINITIONS::=BEGINIMPORTSMODULE-IDENTITY,Integer32FROM SNMPv2-SMI
TEXTUAL-CONVENTIONFROM SNMPv2-TC
ciscoModules
FROM CISCO-SMI;storageTextualConventions MODULE-IDENTITYLAST-UPDATED"200602060000Z"ORGANIZATION"Cisco Systems, Inc."CONTACT-INFO" Cisco Systems
Customer Service
Postal: 170 W Tasman Drive
San Jose, CA 95134
USA
Tel: +1 800 553 -NETS
E-mail: cs-san@cisco.com"DESCRIPTION"This module defines textual conventions used in
Storage Area Network technology specific mibs."REVISION"200602060000Z"DESCRIPTION"- Updated the description of the following objects:
FcPortTxTypes,
FcNameId."REVISION"200512170000Z"DESCRIPTION"- Added following TCs
FcIfSfpDiagLevelType
FcIfServiceStateType
- Added following enums in FcPortModuleTypes
xfp, x2Short, x2Medium, x2Tall, xpakShort,
xpakMedium, xpakTall and xenpak.
- Added following enums in FcPortTxTypes.
tenGigBaseSr, tenGigBaseLr, tenGigBaseEr,
tenGigBaseLx4, tenGigBaseSw, tenGigBaseLw,
tenGigBaseEw.
- Added following enums in FcIfSpeed
fourG and autoMaxTwoG."REVISION"200405180000Z"DESCRIPTION"Added new textual convention 'InterfaceOperMode'."REVISION"200309260000Z"DESCRIPTION"Obtained the OID for this MIB."REVISION"200308070000Z"DESCRIPTION"Added stPort(15) to FcPortTypes."REVISION"200210040000Z"DESCRIPTION"Added fvPort and portOperDown to FcPortTypes.
Added FcAddress and FcAddressType. "REVISION"200209240000Z"DESCRIPTION"Initial version of this MIB module."::={ ciscoModules 4}
VsanIndex ::=TEXTUAL-CONVENTIONSTATUScurrentDESCRIPTION"The VSAN id of a VSAN which uniquely identifies
a VSAN within a fabric. VSAN id is 12-bit
wide; so theoretically, 4096 VSANs can be defined in
a fabric and this device can be part of. However, VSAN
numbers 0 , 4094 and 4095 are reserved."SYNTAXInteger32(1..4094)DomainId ::=TEXTUAL-CONVENTIONSTATUScurrentDESCRIPTION"The Domain Id of the switch. This is assigned
dynamically if the Domain Manager is enabled on
the switch or could be configured statically by
the user."SYNTAXInteger32(1..239)DomainIdOrZero ::=TEXTUAL-CONVENTIONSTATUScurrentDESCRIPTION"The Textual convention is an extension to
textual convetion 'DomainId'. It includes
the value '0'in addition the range 1-239.
Value '0' indicates that Domain Id has
been neither configured nor assigned."SYNTAXInteger32(0..239)FcAddressId::=TEXTUAL-CONVENTIONSTATUScurrentDESCRIPTION"Represents Fibre Channel Address ID, a 24-bit
value unique within the address space of a Fabric."SYNTAXOCTETSTRING(SIZE(3))FcNameId::=TEXTUAL-CONVENTIONSTATUScurrentDESCRIPTION"Represents the World Wide Name (WWN) associated with
a Fibre Channel (FC) entity. A WWN is a 64 bit address
to uniquely identify each entity within a Fibre Channel
fabric."REFERENCE"Fibre Channel Framing and Signaling (FC-FS) Rev 1.70
- Section 14 Name_Indentifier Formats."SYNTAXOCTETSTRING(SIZE(8))FcNameIdOrZero::=TEXTUAL-CONVENTIONSTATUScurrentDESCRIPTION"The World Wide Name (WWN) associated with a Fibre Channel
(FC) entity. WWNs were initially defined as 64-bits in
length. The latest definition (for future use) is 128-bits
long. The zero-length string value is used in circumstances
where the WWN is unassigned/unknown."SYNTAXOCTETSTRING(SIZE(0 | 8 | 16))FcClassOfServices ::=TEXTUAL-CONVENTIONSTATUScurrentDESCRIPTION"Represents the class of service capability of an
NxPort or FxPort."SYNTAXBITS{ classF(0), class1(1), class2(2), class3(3),class4(4), class5(5), class6(6)}FcPortTypes ::=TEXTUAL-CONVENTIONSTATUScurrentDESCRIPTION"Represents fibre channel port types:
auto (1) - Mode is determined by port initialization
scheme.
fPort (2) - Fibre channel fabric port.
flPort (3) - Fibre channel arbitrated loop port.
ePort (4) - Fabric Expansion port.
bPort (5) - Bridging port.
fxPort (6) - This port can only be f_port or fl_port.
sdPort (7) - SPAN destination port. SD_ports transmit
traffic copied from one or more source ports
for monitoring purposes.
tlPort (8) - Translation loop port.
nPort (9) - Fibre channel N port.
nlPort (10) - Fibre channel NL port.
nxPort (11) - This port can only be n_port or nl_port.
-- read only port types.
tePort (12) - Trunking e_port.
Note: A port which is administratively set
to 'ePort', will operationally have type
'tePort' if fcIfOperTrunkMode has the value
'trunk'.
fvPort (13) - Virtual Port.
portOperDown (14) - port operationally down
If a port is operationally down, the
port mode is unknown. In such cases
the operational port mode is shown
as 'portOperDown'.
stPort (15) - SPAN Tunnel destination port."SYNTAXINTEGER{auto (1),fPort (2),flPort (3),ePort (4),bPort (5),fxPort (6),sdPort (7),
tlPort (8),nPort (9),nlPort (10),nxPort (11),tePort (12),fvPort (13),portOperDown (14),stPort (15)}FcPortTxTypes ::=TEXTUAL-CONVENTIONSTATUScurrentDESCRIPTION"Represents port transciever technology types.
unknown (1) - unknown
longWaveLaser (2) - 1550nm laser
shortWaveLaser (3) - 850nm laser
longWaveLaserCostReduced (4) - 1310nm laser
electrical (5) - electrical
tenGigBaseSr (6) - 10GBASE-SR 850nm laser
tenGigBaseLr (7) - 10GBASE-LR 1310nm laser
tenGigBaseEr (8) - 10GBASE-ER 1550nm laser
tenGigBaseLx4 (9) - 10GBASE-LX4 WWDM 1300nm laser
tenGigBaseSw (10) - 850nm laser
tenGigBaseLw (11) - 1310nm laser
tenGigBaseEw (12) - 1550nm laser
."REFERENCE"IEEE Std 802.3-2005 carrier sense multiple access
with collision detection (CSMA/CD) access method
and physical layer specification."SYNTAXINTEGER{unknown (1),longWaveLaser (2),shortWaveLaser (3),longWaveLaserCostReduced (4),electrical (5),tenGigBaseSr (6),tenGigBaseLr (7),tenGigBaseEr (8),tenGigBaseLx4 (9),tenGigBaseSw (10),tenGigBaseLw (11),tenGigBaseEw (12)}FcPortModuleTypes ::=TEXTUAL-CONVENTIONSTATUScurrentDESCRIPTION"Represents module type of the port connector. This
object refers to the hardware implementation of the port.
The enums are defined as per FC-GS-4 standard.
unknown (1) - unknown
other (2) - other
gbic (3) - gbic (gigabit interface card)
embedded (4) - gbic is part of the line card
and is unremovable
glm (5) - if its a gigabit link module
(GLM). A GLM has a different
form factor than GBIC. GLM is
not supported by our switch.
gbicWithSerialID (6) - If GBIC serial id can be read
gbicWithoutSerialID (7) - If GBIC serial id cannot be read
sfpWithSerialID (8) - If small form factor (SFP)
pluggable GBICs serial id can
be read
sfpWithoutSerialID (9) - If small form factor (SFP)
pluggable GBICs serial id
cannot be read
The following enums are module types for 10 gigabit small
form factor pluggable sfp port connectors.
xfp (10) - xfp
x2Short (11) - x2 short
x2Medium (12) - x2 medium
x2Tall (13) - x2 tall
xpakShort (14) - xpak short
xpakMedium (15) - xpak medium
xpakTall (16) - xpak tall
xenpak (17) - xenpak
."SYNTAXINTEGER{unknown (1),other (2),gbic (3),
embedded (4),glm (5),gbicWithSerialID (6),gbicWithoutSerialID (7),sfpWithSerialID (8),sfpWithoutSerialID (9),xfp (10),x2Short (11),x2Medium (12),x2Tall (13),xpakShort (14),xpakMedium (15),xpakTall (16),xenpak (17)}FcIfSpeed ::=TEXTUAL-CONVENTIONSTATUScurrentDESCRIPTION"Represents the speed of a fibre channel port.
Following are the meanings of the enumerated values:
auto (1) - Negotiate to determine the speed
automatically.
oneG (2) - 1Gbit
twoG (3) - 2Gbit
fourG (4) - 4Gbit
autoMaxTwoG (5) - Negotiate to determine the
speed automatically upto a
maximum of 2Gbit. "SYNTAXINTEGER{auto (1),oneG (2),twoG (3),fourG (4),autoMaxTwoG (5)}PortMemberList ::=TEXTUAL-CONVENTIONSTATUScurrentDESCRIPTION"A list of ifIndex's of the ports that are members of
this list.
The value of this object is a concatenation of zero or
more 4-octet strings, where each 4-octet string contains
a 32-bit ifIndex value in network byte order.
A zero length string value means this list has no
members."SYNTAXOCTETSTRING(SIZE(0..64))
FcAddress ::=TEXTUAL-CONVENTIONSTATUScurrentDESCRIPTION"Represents either the Fibre Channel Address ID or
the World Wide Name associated with a Fibre
Channel (FC) Entity."SYNTAXOCTETSTRING(SIZE(3 | 8))FcAddressType ::=TEXTUAL-CONVENTIONSTATUScurrentDESCRIPTION"Denotes if a Fibre Channel Address is
a World Wide Name (WWN) or a Fibre
Channel Address ID (FCID).
wwn(1) - address is WWN.
fcid(2) - address is FCID."SYNTAXINTEGER{wwn(1),fcid(2)}InterfaceOperMode ::=TEXTUAL-CONVENTIONSTATUScurrentDESCRIPTION"Represents the operational mode of an interface
auto (1) - Mode is determined by port initialization
scheme.
fPort (2) - Fibre channel fabric port.
flPort (3) - Fibre channel arbitrated loop port.
ePort (4) - Fabric Expansion port.
bPort (5) - Bridging port.
fxPort (6) - This port can only be f_port or fl_port.
sdPort (7) - SPAN destination port. SD_ports transmit
traffic copied from one or more source
ports for monitoring purposes.
tlPort (8) - Translation loop port.
nPort (9) - Fibre channel N port.
nlPort (10) - Fibre channel NL port.
nxPort (11) - This port can only be n_port or nl_port.
-- read only port types.
tePort (12) - Trunking e_port.
Note: A port which is administratively set
to 'ePort', will operationally have type
'tePort' if fcIfOperTrunkMode has the value
'trunk'.
fvPort (13) - Virtual Port.
portOperDown (14) - port operationally down
If a port is operationally down, the
port mode is unknown. In such cases
the operational port mode is shown
as 'portOperDown'.
stPort (15) - SPAN Tunnel destination port.
mgmtPort(16) - Mgmt Port.
ipsPort(17) - Ethernet Port.
evPort(18) - FCIP tunnels on Ethernet ports."SYNTAXINTEGER{auto (1),fPort (2),flPort (3),ePort (4),bPort (5),
fxPort (6),sdPort (7),tlPort (8),nPort (9),nlPort (10),nxPort (11),tePort (12),fvPort (13),portOperDown (14),stPort (15),mgmtPort(16),ipsPort (17),evPort (18)}FcIfServiceStateType ::=TEXTUAL-CONVENTIONSTATUScurrentDESCRIPTION"Represents the service state of a Fibre Channel
interface. Following are the meanings of the
enumerated values:
inService (1) - interface is in service and is
allowed to become operational.
outOfService (2) - interface is removed from service
and is not allowed to become
operational."SYNTAXINTEGER{inService (1),outOfService (2)}FcIfSfpDiagLevelType ::=TEXTUAL-CONVENTIONSTATUScurrentDESCRIPTION"Represents the severity level of the SFP
diagnostic information of an interface for
temperature, voltage, current, optical
transmit and receive power."SYNTAXINTEGER{unknown (1),normal (2),lowWarning (3),lowAlarm (4),highWarning (5),highAlarm (6)}END